If it is a small hole or crack, then it is a minor issue that needs to be corrected generally by replacing the furnace or heat exchanger. Some people choose to live in denial of the seriousness of a cracked heat exchanger. The appearance of a black carbon buildup on the furnace. Signs and symptoms of a cracked gas furnace heat exchanger change in flame appearance. I definitely have a cracked primary heat exchanger and will be replacing our furnace. Not having proper maintenance performed by a skilled professional will also take years off the life of a heat exchanger. Mar 11, 20 as a homeowner, getting the news that your heat exchanger is cracked is a bit of a harsh blow. The gases will continue to seep into your homes air. This article is about ways to determine if a gas furnace has a cracked heat exchanger. Every cracked heat exchanger needs to be replaced, either by replacing the heat exchanger itself or by replacing the entire furnace. Dec 02, 2015 proper diagnosis of a failed or cracked heat exchanger. You know its serious and you know you need to do something about it. A faulty heat exchanger will produce a strong and unpleasant odor that smells similar to formaldehyde. The extra air will cause the oxygen reading to change notably.
Look for signs that the metal has been overheated, or symptoms of longterm metal fatigue. Diagnosis of a heat exchanger crack typically starts with a noheat service call. Because it allows the exhaust fumes inside the exchanger to leak into the air. Have you heard this one recently, you have a cracked heat exchanger and your furnace has to be replaced, today. Gas furnace pressure switch problems gray furnaceman. I noticed the other day the my how water boiler had flames dancing around underneath the heat exchanger. Many companies, upon finding a cracked heat exchanger, will shut your furnace down so you cannot run it. Proper diagnosis of a failed or cracked heat exchanger. Dec 23, 2019 look out for certain symptoms that point to a cracked heat exchanger, such as. In an attempt to sell new furnaces, numerous heating contractors will lie about cracked heat exchangers. Cracks in the heat exchanger are a serious problem and one that should not be ignored both for the safety of your home and for the longevity of your furnace. A normally operating gas furnace has a steady blue flame. A well qualified hvac technician will look for a furnace cracked heat exchanger during a maintenance check.
Jan 09, 2017 be good to your heat exchanger inside a heat exchanger is fire, soot, and carbon monoxideall substances that can escape if it cracks. Normally, the flame of a normal gas furnace will appear blue. We are finding a large number of failed secondary heat exchangers in these particular models, which relate to a failure of a polypropylene coating. Signs and symptoms of a cracked gas furnace heat exchanger.
Today we answer your question of if there are symptoms of a cracked heat exchanger in your gas furnace. For this reason, i want to share with you some of the common symptoms and causes of a cracked heat exchanger in a furnace. Dec 21, 2011 cracked heat exchanger diagnosis for your furnace in indianapolis by. The furnace is a carrier thatunder a settlementcarrier agreed to either pay the labor and parts to replace the secondary heat exchanger, including labor, or to give a credit to a new furnace installation. Remove it from the furnace, and examine it in the light.
For carbon monoxide to leak from a cracked heat exchanger, two things need to be happening. Unless you are one of the top 3% of people who have all the money, replacing the furnace is going to hurt the pocket book if you have not planed for it, but it has to be done. Hart home comfort offers affordable home heating services you can trust. This smell can cause headaches, as well as other physical symptoms in humans. A furnace heat exchanger works by literally exchanging or transferring the heat created in the combustion chamber to the exterior of the unit, where it is then blown through the ductwork throughout the house. A malfunctioning heat exchanger will often create an unpleasant and strong odor that smells similar to formaldehyde. Dangerous cracked heat exchangers in furnaces carbon monoxide detectors and cracked heat exchangers. Heat safety is paramount so have your furnaces inspected immediately for a cracked heat exchanger. Some holes or small openings may have been there for years. How to tell if furnace heat exchanger is cracked 1. This odor alone can cause severe headaches and other physical symptoms in humans.
Basically, the heat exchanger is where the furnace heats the air. The heat exchanger is cracked or otherwise has an air leak. Diagnosis of a heat exchanger crack typically starts with a no heat service call. The heat of the combustion gas raises the temperature of the metal, and as the air from the blower passes around it, heat transfers to it. The cause of cracked heat exchangers avoid this common scam. Furnace heat exchanger issues can lead to a system breakdown orworsea. Dec 30, 2019 in most cases, the flue gases in your furnace will not contain carbon monoxideits not a typical byproduct of gas combustion in the furnace. This is because air is leaking through the crack in the heat exchanger into the combustion chamber. This trips a safety switch and shuts down the furnace. Weve met with lots of homeowners looking for a second opinion about a supposedly cracked heat exchanger. Signs your heat exchanger may be cracked on your gas furnace. There are certain signs to look for to determine if the heat exchanger has been cracked. Of all the components of a gas furnace, the heat exchanger is one of the most important.
Signs your heat exchanger is cracked romaniuk edmonton. If there is a crack in the furnaces heat exchanger, there will be some signs and symptoms that are normally evident concerning the furnace. Dec 04, 2016 gas furnace heat exchanger clogged problem what it looks like and burn spots. When a furnace has a cracked heat exchanger, can it be. For carbon monoxide to leak from a cracked heat exchanger, two things need.
This article is about ways to determine if a gas furnace has a cracked heatexchanger. If you smell a formaldehydelike odor, you should immediately call a professional for a furnace inspection. Classic symptom of a cracked heat exchanger youtube. Indianapolis hvac cracked heat exchanger diagnosis furnace. If you or other family members experience continual recurring headaches or flulike symptoms, this could indicate a cracked heat exchanger. If your repair technician just gave you the bad news that your furnace has a cracked heat exchanger, and you said, a cracked what. In the video above the furnace techs says the oxygen reading could rise as high as. This means that your heating system is working well. If you notice any of these signs, its best to call a furnace service company to check your furnaces heat exchanger.
Theres a lot of good info on there, but some of it is misleading and there are a lot of straw man arguments made. This article is going to go over what a heat exchanger is, why it cracks and what you can do about it if you have a home warranty. Stress cracks and other signs of wear and tear on external parts of your furnace can be signs that internal parts are suffering the same wear. The your heat exchanger is cracked so your furnace must be replaced. Experts always recommend good care and maintenance for. The heat exchanger is a metal container inside the furnace that collects hot combustion gas from the burners. When a heat exchanger becomes damaged and the combustion fumes and gases mix with the clean air, serious consequences can result. The secondary heat exchanger is designed to extract the maximum remaining heat from the fuel source, resulting in a normal condensation reaction.
From what ive been told and read, it could mean that my heat exchanger is cracked. A heat exchanger crack in a residential furnace large enough. In most cases, if the heat exchanger is cracked, your hvac company will recommend replacing the entire furnace. A burner with a moving yellow flame can mean that the burner is dirty or that the heat exchanger is cracked. This will be detected with a combustion gasses tester. The american gas association has even put this in writing they say any visible crack or hole is reason for requiring replacement of the heat exchanger or furnace. Brian schutt december 21, 2011 chances are if youre reading this, youve had a technician out to your home and theyve told you you have a crack or rupture in your heat exchanger. When there is a call for heat, and the inducer starts, if, after 12 minutes, the inducer shuts off and pressure switch code comes on, the pressure switch is not closing. You can just have the heat exchanger replaced, but it is an expensive repair, and a new furnace is often the smarter investment. Before you can do any repairs, you should make sure that you check over your furnace heat exchanger thoroughly. Jan, 2020 the heat exchanger in your furnace heats air traveling from one end to the other. If a heatexchanger is cracked, air forced into the combustionchamber will cause the oxygen reading in the furnaces exhaust to rise to abnormal levels.
Often when cracks are present in a heat exchanger, soot from the combustion process will seep through and discolor the metal. However, if it turns yellow, it could be because the burner needs cleaning or worse, it could be a cracked heat. Home warranties and cracks in your furnaces heat exchanger. A furnace with a cracked heat exchanger will definitely produce carbon monoxide and poses an immediate danger. Dont worry though, there are some simple steps you can take to avoid your heat exchanger failing before the lifespan of your furnace is up, including. Its not unlike a doctor telling you about the c word. The moisture in burned gas is slightly acidicabout the same level as a tomatoand this acid will corrode a heat exchanger over time. If there is evidence of soot buildup inside of the furnace, then its very possible that there could be a crack in the heat exchanger. This is due to the combustion process being incomplete.
The most toxic of these exhaust fumes is carbon monoxide, which can cause severe health problems. Oct 30, 2019 heat exchangers are built to last 10 to 20 years, but that period could be shorter if an hvac system is used more often than the norm. The heat exchanger is aptly named it collects air through the ventilation system and exchanges it to heat with the help of the furnace burners. What are some tell tale signs of a cracked heat exchanger. Avoid these 4 common furnace repair scams oconomowoc boiler. Residential 80% furnaces made in the last 30 years with airconditioning coils on the discharge outlet of the furnace do not allow carbon monoxide to enter the indoor air stream. Recurring nose andor eye irritation, sleepiness, disorientation, and nausea would also all fall under this source umbrella. The flames appearance changes a furnace flame should be blue in appearance. Many hvac contractors find cracked heat exchangers using visual analysis and use the results to recommend furnace replacement. Flame roll out left burner due to hole in heat exchanger.
Jan 10, 2018 they can come inspect your furnace and determine if you do indeed have a cracked heat exchanger. A cracked heat exchanger allows air from the furnace blower to interfere with the flame causing it to flutter or even roll out. If you or other family members experience continual recurring headaches or flu like symptoms, this could indicate a cracked heat exchanger. When the the cycle stops, i dont hear any hissing after which could mean water leaking out of the exchanger. Heat exchangers are made of a set of metal tubes or coils that. Furnace heatexchanger crack signs your furnace has one. The house with 2 bad furnaces cracked heat exchangers. It is usually an indicator of more trouble in the future, and should not be taken lightly.
A heat exchanger is made of thin metal, and as it heats up from the combustion of the furnace, it transfers the heat to the air being distributed through the house by the blower 3. If your heat exchanger has cracks, these cracks cause your furnace to perform inefficiently. Although you should certainly not wait until your carbon monoxide detector sounds to determine if your heat exchanger is broken, if you do get an alarm, it is a strong sign that damage is present. A warning about cracked heat exchangers in gas furnace.
703 1294 1375 1661 1456 548 1640 340 1284 1228 1011 762 1634 469 342 1474 1545 473 1484 180 293 408 8 1036 543 400 509 965 593 38 493 7 534 1348 911 1055 513 1383 1111 674 778 1074 619